Animal breathing safety monitor
According to the needs of clinical terminal, Dolphin Medical has developed high-precision pet breathing safety monitors based on the needs of clinical end-uses and accumulated technology for many years. It is used in pet hospitals, scientific research units, laboratories, biopharmaceutical research, clinical teaching, animal husbandry institutions, etc., to help pet hospitals improve anesthesia. Safety, making the management of respiratory anesthesia easier.
Features:
Monitor animal breathing to ensure animal safety!
Simple connection, can match all animal anesthesia machines
Used in the respiratory safety monitoring of small animals, dogs, cats and large animals of 0.1-100kg
9-inch high-definition touch screen, displays alarms, waveforms, and all set parameters
PEEP monitoring with positive end expiratory pressure
Double waveforms, accurately grasp the animal's breathing state
With the function of monitoring pet suffocation and alarm, making the operation process safer and more efficient
Three-level high and low-level sound and color alarm
Adjustable alarm volume with quick mute button
Protection lock shortcut keys to prevent accidental touch
Optional oxygen concentration FIO2, blood oxygen SPO2 and end-tidal carbon dioxide ETCO2
The tidal volume is monitored at the end of the exhalation, which is more accurate.
It can monitor peak pressure, average pressure and end-tidal pressure
Technical specifications
Monitoring parameters:
Peak pressure
Mean pressure
End-tidal pressure
Ventilation volume
Expiratory tidal volume
Inhaled tidal volume
Breathing rate
Inhaled oxygen concentration
Waveform monitoring:
Pressure waveform
Flow waveform
Alarm information monitoring
Peak pressure upper and lower limit violation alarm information
The upper and lower tidal volume exceeds the limit alarm
The upper and lower ventilation limit exceeds the alarm
Suffocation alarm message
End-tidal pressure upper and lower limit alarm
Oxygen concentration upper and lower limit alarm (optional)
Blood oxygen upper and lower limit alarm (optional)
End-tidal carbon dioxide upper and lower limit alarm (optional)
Adjustment range setting | |||
Lower limit | Upper range | Recommended range | |
Peak pressure{cmH20} | 0 | 60 | 0—40 |
Tidal volume{mL} | 0 | 1500 | 5—1500
|
Minute ventilation volume{L/min} | 0 | 40 | 0.1—30 |
Oxygen concentration {%} | 15 | 100 | 21—100 |
End-tidal pressure{cmH20} | 0 | 25 | 1—10 |
Frequency{bpm} | 1 | 200 | 2—35 |
Suffocation time{s} | 3 | 20 | 3—10 |